Model Number Identification

To process all enquiries and orders with the correct instrument it is essential to forward the following specifications:

  • Type of gas
  • Flow range
  • Operating pressure (for controllers inlet and outlet pressure)
  • Operating and ambient temperature
  • Type of process connection and seals
  • Power supply
  • Requested output signal (for controllers input and output signal)

Actual model number identification according to the file enclosed:


    

   Model Number Identification D-6300

   Model Number Identification D-6200 and D-5100


Example 1:

 D-6230-HGB-BB-AV-24-0-S-A


Model:

Mass flow meter with Ø 8mm bore

Power supply:

24 Vdc

Output signal:

4 ... 20 mA

Process connection:

G 1/4

Body material:

Aluminium

Sealing material:

Viton

Flow rate:

1 ... 20 ln/min

Type of gas:

Air

Display:

No display

Analogue instrument with standard sensor

24 Vdc



 Customer data for calibration:


Operating pressure:

4 bar

Operating temperature:

20° C



Example 2:

 D-5111-FAA-BB-SE-99-C-S-A

Model:

Mass flow controller for small flow rates

Power supply:

15 Vdc

Output signal:

0 ... 5 Vdc

Process connection:

G 1/4

Body material:

SS316

Sealing material:

EPDM

Flow rate:

Customer specific

Type of gas:

Customer specific

Display:

display for flow in ln/min

Analogue instrument with standard sensor

15 Vdc



 Customer data for calibration:


Type of gas:

NH3

Flow rate:

0,2 ... 0,3 m³n/h

Operating inlet pressure:

3 ... 5 bar

Operating outlet pressure:

1 ... 2 bar

Operating temperature:

15° C



Technical changes and alterations in construction are reserved!